rem Engineering, Inc., P.O. Box 1955, Roswell GA 30077, (770) 594-9393, Fax: (770) 594-9368

CASE STUDIES

 
Gas Turbines
Proposed for the
Arkansas Plant (click on photo to enlarge)
   

COGENERATION STUDY FOR LARGE ARKANSAS POULTRY COMPANY

Three gas turbines and three HRSG's generate 7.5 MW of electricity and provide process steam.

rem investigated several cogeneration possibilities for a large Arkansas based poultry company. Gas turbines equipped with waste heat boilers, diesel engines, and spark ignited, natural gas fired engines were three scenarios rem analyzed. A plant design that combined three gas fired, Allison 501 KB, combustion turbines, each equipped with a waste heat recovery boiler, was selected.

rem provided the thermodynamic design, selected suitable equipment (new or used), priced the facility, selected installation contractors and developed proforma. By working closely with our client, rem addressed independent concerns and needs. A well designed plant will achieve or exceed the client's process and economic goals.

The proposed plant, using three gas turbines with HRSGs, and the returns it generated were attractive to our customer. This study/proposal was accepted by the client and used to renegotiate lower utility rates. This project saved millions of dollars in annual electric bills for our customer.

Mr. Jim Doss was our contact at this large poultry company. He has agreed to serve as a reference for rem . Mr. Doss can be contacted by fax at (501) 290-4067.

ˆ back to top | back to Case Studies